EPSON

Replacing the Roller Assembly Kit

It is recommended that you replace the parts on the roller assembly kit after every 100,000 scans.
Note:
You can check the number of scans by starting EPSON Scan Settings and clicking Maintenance.
Removal part
Part number
Roller Assembly Kit
B12B813421
To replace the roller assembly kit, follow the steps below:
Turn off the scanner.
Remove all paper from the input tray.
Unplug the AC adapter from the scanner.
Pull the lever and open the scanner cover.
Press the hook on the separation pad, then remove the installed separation pad.
Caution:
Do not touch the pick spring. Hold the new separation pad holder as shown below.
Insert the bottom side of the new separation pad first, then press the hook on the separation pad to attach to the correct position.
Press the hook on both sides of the paper feed roller cover, then open the cover.
Slide and remove the installed paper feed roller.
Caution:
Do not touch the surface of the paper feed roller. Hold the new paper feed roller as shown below.
Slide the new paper feed roller onto the spool.
Caution:
Do not install the paper feed roller in reverse direction.
Close the paper feed roller cover, then close the scanner cover.
Turn on the scanner.
Start EPSON Scan Settings. Then, click Maintenance.
Click Reset on the right of the Number of Scans.
Click OK.