Replace the
scanner rollers when the number of scans exceeds the life cycle of
the rollers. Check the scanner roller counter to see when you need
to replace the rollers.
Turn off
the scanner.
Unplug
the AC adapter.
Disconnect any connected cables.
Pull
down on the cover open lever and open the scanner cover.
Press
down on the pickup roller cover latch and pull up the cover to
remove it.
Pull
down the tab on the pickup rollers and slide the
rollers to the right to remove
them.
To
install the new pickup rollers, align the notches on
the roller unit and slide it to the left. Press up on the tab to
secure the rollers.
Align
the bottom edge of the pickup roller cover into the notches as
shown and press it down until it clicks into place.
Note: If you are
not able to close the cover, the pickup rollersare not installed correctly. Remove the roller unit
and reinstall it, then try to close the cover again.
Squeeze
the tabs on the sides of the separation roller cover and open the
cover.
Caution:
Be careful not to apply too much force when
opening the cover.
Slide the separation roller to the
left and remove it.
To
install a new separation roller, insert the end of the roller into
the hole on the right side and lower the other end of the roller
into place.
Close
the separation roller cover until you hear it click into
place.
Note: If you are
not able to close the cover, the roller is not installed correctly.
Remove the roller and reinstall it, then try to close the cover
again.