You can
perform a manual feed adjustment from the product control panel if
you can still see banding after performing an automatic feed
adjustment.
Press
the Menu
button.
Press
the OK button to select
Media Setup.
Press
the down arrow button to select Customize
Settings and press the OK button.
Press the down arrow button to select
Media Adjust and press the
OK button.
Press the down arrow button to select
Manual and press the
OK button.
Press the OK button to select Feed Adjustment.
Press the up or down arrow button to
select an adjustment pattern and press the OK button.
500mm Pattern: We recommend
starting with this pattern. Make sure the length of the loaded
media is at least 38 inches (970 mm).
250mm Pattern: Make sure the
length of the loaded media is at least 28 inches (720 mm).
100mm Pattern: Make sure the
length of the loaded media is at least 22 inches (570 mm).
Standard: Make sure the length
of the loaded media is at least 13 inches (330 mm).
Your product prints an adjustment pattern and automatically feeds
the media to viewing position.
Do the following to adjust the media
feed:
If you selected 500mm Pattern
(recommended), 250mm Pattern, or
100mm Pattern, measure the distance
between the + symbols in each test
pattern as shown.
On the product control panel, enter the value for the distance
between the + symbols and press the
OK button.
If you selected Standard, your
product prints two groups of adjustment patterns (A and B).
On the product control panel, enter the values with the least
amount of overlapping or gaps for each group and press the
OK button.