Light Source Calibration

Run Now

Starts light source calibration to optimize the color balance of the currently projected image. You may not be able to start calibration if the projector's environmental temperature is out of range. (Wait 20 minutes after turning on the projector before starting calibration for the best results.)

Light Source Calibration does not start in the following cases.
  • If the projector is not used continuously for more than 20 minutes
  • If the surrounding temperature gets too high, and the brightness has been automatically dimmed.
  • If you use the following functions and the brightness of the light source declines to a specific level or lower.
    • Dynamic Contrast
    • Lights-Out Control
    • Shutter
    • If Brightness Settings is set to 30% or less.
Run Periodically
Set to On to perform light source calibration periodically every 100 hours of usage.

When set to Off to maintain the projected image that has been adjusted using Multi-Projection, perform calibration using Run Now or set a Light Source Calibration event to perform it periodically on the Schedule Settings screen.

Schedule Settings
Displays the Schedule Settings screen. Set a Light Source Calibration event to run periodically.
Last Run
Displays the date and time of the last light source calibration.