Note: Specifications are based on having the standard zoom lens (ELPLM15) installed. The lens is not included with the projector. Turn High Altitude Mode on when operating the projector above 4921 feet (1500 m).
Temperature (when using a single projector) Operating:

Up to 7500 feet (2286 m): 41 to 95 °F (5 to 35 °C)

7500 to 10000 feet (2286 to 3048 m): 41 to 86 °F (5 to 30 °C)

Storage:

14 to 140 °F (–10 to 60 °C)

Thermal output (max.) EH-QL3000W/EH-QL3000B:

100 to 120 V area: 1,540 BTU/h

220 to 240 V area: 1,486 BTU/h

EH-QL7000W/EH-QL7000B:

100 to 120 V area: 2,162 BTU/h

220 to 240 V area: 2,081 BTU/h

Airflow (max.) 169 CFM
Humidity (relative, non-condensing) Operating: 20 to 80%

Storage: 10 to 90%

Operating altitude Up to 10000 feet (3048 m)

Above 4921 ft (1500 m), use High Altitude Mode