If only a partial computer image appears, try the
following solutions:
- For VGA connections, press the Auto button on the remote control to optimize
the image signal.
- Make sure
you selected the correct Screen
Type setting for the screen you are using.
- Make sure the Scale setting in the Signal menu is turned
off.
- Make sure the Resolution setting in the Signal menu is set
correctly for the input signal.
- Try adjusting the image position using the
Position setting in the Signal
menu.
- Press the
Aspect button on the remote
control to select a different image aspect ratio.
- Check the Blanking
setting in the Signal menu.
- Check your
computer display settings to disable dual display and set the
resolution within the projector's limits. (See your computer manual
for details.)
- Check the
resolution assigned to your presentation files to see if they are
created for a different resolution than you are projecting in. (See
your software help for details.)