Settings on the Notifications menu let you receive an e-mail notification if a problem or warning occurs in the projector.
Network >
Network Configuration
>
Notifications
Setting |
Options |
Description |
---|---|---|
Mail Notification |
On Off |
Set to On to send an e-mail to the preset addresses when a problem or warning occurs with a projector. |
SMTP Server |
IP address |
Enter the IP address for the projector's SMTP server using 0 to 255 for each address field. Do not use these addresses: 127.x.x.x, 192.0.2.x or 224.0.0.0 through 255.255.255.255 (where x is a number from 0 to 255). |
Port Number |
1 to 65535 (default is 25) |
Select a number for the SMTP server Port Number. |
From |
Up to 32 alphanumeric characters Up to 64 alphanumeric characters from the Web browser (do not use " ( ) , : ; < > [ \ ] spaces) |
Enter the e-mail address of the sender. |
Address 1 Setting Address 2 Setting Address 3 Setting |
Enter the e-mail address, and select the alerts you want to receive. Repeat for up to three addresses. |
|
SNMP |
On Off |
Set to On to monitor the projector using SNMP. To monitor the projector, you need to install the SNMP manager program on your computer. SNMP should be managed by a network administrator. |
Trap IP Address 1 Trap IP Address 2 |
IP address |
Enter up to two IP addresses to receive SNMP notifications, using 0 to 255 for each address field. Do not use these addresses: 127.x.x.x or 224.0.0.0 through 255.255.255.255 (where x is a number from 0 to 255). |
Community Name |
Up to 32 alphanumeric characters |
Set the SNMP community name. |