Introduction to Your Projector
Using Basic Projector Features
Blending Using the Epson Projector Professional Tool Software and the Optional Camera
Simple Blending Using the Projector's Menu and the Optional External Camera
Stacking Using the Epson Projector Professional Tool Software and the Optional Camera
Stacking & Blending Using the Epson Projector Professional Tool Software
Light source calibration automatically adjusts any difference between the white balance and the brightness level of the light source. You should perform light source calibration every 100 hours of projector usage. You can also schedule automatic calibration or run the light source calibration manually using the menus.
Automatic light source calibration may not start in the following conditions:
Within 30 minutes of turning on the projector.
When using direct shutdown.
When you have used the projector continuously for over 24 hours.
When the projector brightness is automatically dimmed due to high temperatures.
Turn on the projector.
Press the Menu button, select the Management menu, and press Enter.
Select Light Source Calibration and press Enter.
Select any of the following:
To run the light source calibration now, select Run Now.
To automatically run the light source calibration every 100 hours of projector usage, select Run Periodically and set it to On.
To check the last time the projector performed a calibration, see Last Run.
If you use the projector continuously for more than 24 hours or use direct shutdown regularly, select Schedule Settings to schedule calibration of the light source periodically.
To schedule automatic calibration, select Schedule Settings.
When you are finished, press Menu to exit the menus.